Specifications

37
BCN-B11127-478*
(2) Write instruction codes (80000 to FFFFh)
Instruction code
(RWw2)
Instruction code
processing
Instruction code
executio n completion
(RX9)
Answer code
(RWr2)
W
riting data
(RWw3)
Instruction code
execution demand
(RY9)
Write in execution
Set the write instruction code to Instruction code (RW
W2
) and the data to be written (data to be
executed) to Writing data (RW
W3
) in hexadecimal, and turn Instruction code execution demand (RY9)
to “1” (ON).
Turning RY9 to “1” (ON) sets the data set in Wiring data (RW
W3
) to the item corresponding to the
write instruction code. When write is executed, Instruction code execution completion (RX9) turns to
“1” (ON).
If the instruction code not in the specifications is set to Instruction code (RW
W2
), the corresponding
error code (
1 ) is set to Answer code.
Turn Instruction code execution demand (RY9) to “0” (OFF) after Instruction code execution
completion (RX9) has turned to “1” (ON).