Specifications
35
BCN-B11127-478*
(2) When 2 stations are occupied
Data HOLD
ON
OFF
Monitor 1
(
RWw0
)
Monitor 2
(
RWw1
)
Monitor execution
d
emand
(RY8)
ON
Monitorin
g
Monitor 1 data
Under 16bit
(
RWr0
)
A
nswer code
(
RWr2
)
Monitor 1 data
U
pp
er 16bit
(
RWr1
)
Monitor 2 data
Under 16bit (RWr5)
Monitor 2 data
OFF
(RX8)
Under 16bit (RWr6)
Set the monitor codes to Monitor 1 (RW
W0
) and Monitor 2 (RW
W1
) and turn Monitor output execution
demand (RY8) to “1” (ON). Turning RY8 to “1” (ON) sets the next data. 32-bit data are all divided into the
upper 16 bits and lower 16 bits, and set to the remote register. Data are all hexadecimal numbers. At this
time, Monitoring (RX8) turns to “1” (ON) at the same time.
Monitor data 1 under 16 bit (RW
R0
): Lower 16 bits of data demanded by Monitor 1 (RW
W0
)
Monitor data 1 upper 16 bit (RW
R1
): Upper 16 bits of data demanded by Monitor 1 (RW
W0
)
Monitor data 2 under 16 bit (RW
R5
): Lower 16 bits of data demanded by Monitor 2 (RW
W1
)
Monitor data 2 upper 16 bit (RW
R6
): Upper 16 bits of data demanded by Monitor 2 (RW
W1
)
A sign is set if data does not exist in RW
R1
RW
R6
. A “ ” sign is indicated by “0000”, and “ ” by “FFFF”.
The monitor data set to the remote register are always updated while RX8 is “1” (ON).
When RX8 turns to “0” (OFF), the data set to Monitor data RW
R0
, RW
R1
, RW
R5
, RW
R6
are held.
If the monitor code not in the specifications is set to either Monitor 1 (RW
W0
) or Monitor 2 (RW
W1
), the
corresponding error code (
1) is set to Answer code.