Specifications

33
BCN-B11127-478*
4.5.5 Setting the external input signals
Using parameter No. 116, 117 and 118, you can assign the input signals as the external input signals.
The signals assigned as the external input signals cannot be used in CC-Link.
Parameter No. 116
0
Servo On
Alarm Reset
0
0
0
0
BIN
Si
g
nal name
Initial value
0
HEX
BIN 0: Used in CC-Link
BIN 1: Used as CN1A/CN1B external input si
g
nal
Forward rotation stroke end
Reverse rotation stroke end
Automatic/manual operation mode
0
BIN
Si
g
nal name
Initial value
0
HEX
Forward rotation start
Reverse rotation start
0
0
0
0
BIN
Si
g
nal name
Initial value
0
HEX
0
0
0
Parameter No. 117
0
Internal torque limit selection
Proportion control
Temporary stop / Re-start
0
0
0
0
BIN
Signal name
Initial value
0
HEX
BIN 0: Used in CC-Link
BIN 1: Used as CN1A/CN1B external input signal
0
0
0
0
BIN
Signal name
Initial value
0
HEX
Cynchronous operation start
0
Parameter No. 118
0
Position block No. Selection 1
0
0
0
0
BIN
Signal name
Initial value
0
HEX
BIN 0: Used in CC-Link
BIN 1: Used as CN1A/CN1B external input signal
0
0
0
0
BIN
Signal name
Initial value
0
HEX
0
Position block No. Selection 2
Position block No. Selection 3
Position block No. Selection 4