Specifications

26
BCN-B11127-478*
Code No. Item/Function
Reading data (RW
R3
) contents
(Servo amplifier
PLC)
0081 Energization time
Reads the energization time from
shipment.
Returns the energization time [h].
0082 Power ON frequency
Reads the number of power-on times from
shipment.
Returns the number of power-on times.
00A0 Ratio load inertia
Reads the estimated ratio of load inertia
moment to servo motor shaft inertia
moment.
Returns the estimated ratio of load inertia moment to servo motor
shaft inertia moment [times].
00B0 Within-1-revolution position data (CYC0)
Cycle counter value of absolute home
position under 16 bit
Return unit [pulses]
00B1 Within-1-revolution position data (CYC0)
Cycle counter value of absolute home
position upper 16 bit
Return unit [pulses]
00C0 Error parameter No./Point block No.
reading
Parameter No. or block No.
0
1: Parameter
2: Position block
3: Speed block
Ex. : The data will be “0209” when position block No.9 has an
error.
0200
to
027C
Parameter setting
Reads the values set in parameter No. 0 to
124.
The decimal value converted from the 2
lower digits of the code No. corresponds to
the parameter No.
The setting of the requested parameter No. is returned.
For parameter No. 1, “F” enters the blank digits. For example,
setting of “13” will be “FF13”.
The range of reading parameters depends on the setting in
parameter No. 19. An error code will be respond when try to read
blocking parameter in No.19.