Specifications

21
BCN-B11127-478*
2) Output (Servo amplifier
PLC)
Note that the data set to RWrn and RWrn+1 depends on whether 1 station or 2 stations are occupied.
If you set inappropriate code No. or data to the remote register input, the error code is set to Answer
code (RWrn+2). Refer to the error code.
When 1 station is occupied
Remote register Signal name Description
RWrn Monitor 1 data The data of the status indication item set to RWwn is set.
RWrn+1 Monitor 2 data The data of the status indication item set to RWwn+1 is set.
RWrn+2 Answer code “0000” is set when the codes set to RWwn RWwn+3 are executed
normally.
RWrn+3 Reading data Data corresponding to the read code set to RWwn+2 is set.
When 2 stations are occupied
Remote register Signal name Description
RWrn Monitor 1 data under 16bit The lower 16 bits of the data of the status indication item set to RW
Wn
are set.
RWrn+1 Monitor 1 data upper 16bit The upper 16 bits of the data of the status indication item set to RW
Wn
are set. A sign is set if there are no data in the upper 16 bits.
RWrn+2 Answer code “0000” is set when the codes set to RW
Wn
RW
Wn+6
are executed
normally.
RWrn+3 Reading data Data corresponding to the read code set to RW
Wn+2
is set.
RWrn+4
RWrn+5 Monitor 2 data under 16bit The lower 16 bits of the data of the status indication item set to RW
Wn+1
are set.
RWrn+6 Monitor 2 data upper 16bit The upper 16 bits of the data of the status indication item set to RW
Wn+1
are set. A sign is set if there are no data in the upper 16 bits.