Specifications

19
BCN-B11127-478*
Device #
Signal name Description
1 station
occupied
2 stations
occupied
Note
Point block
output (bit 0)
RX(n+2)2
Point block
output (bit 1)
RX(n+2)3
Point block
output (bit 2)
RX(n+2)4
Point block
output (bit 3)
RX(n+2)5
Point block
output (bit 4)
Point block No. is set after position complete.
This signal will be turns off if;.
1) Power off
2) Servo off
3) In zeroing
4) After zeroing completion
Also is will be hold previous status if;
1) Changed operation mode
2) In manual operation
3) In fast zeroing
The data table is as follows;
Point table# RY26 RY25 RY24 RY23 RY22
1 0 0 0 0 1
2 0 0 0 1 0
3 0 0 0 1 1
4 0 0 1 0 0
: : : : : :
29 1 1 1 0 1
30 1 1 1 1 0
31 1 1 1 1 1
RX(n+2)6