Specifications

12
BCN-B11127-478*
4.4 Servo amplifier setting
4.4.1 Servo amplifier side operation modes
The MR-J2S-T01 with MR-J2S-CP-S099 has the following operation modes:
Operation mode Description
CC-Link operation mode
CC-Link communication functions are used to operate the servo with the PLC programs.
Test operation mod
The configuration S/W or push button on the front panel in the servo amplifier is
operated to test-run the servo.
4.4.2 Operation mode changing
(1) Operation mode changing conditions
Change the operation mode after making sure that:
(a) The servo motor is at a stop.
(b) The forward rotation start (RY
n1
) or reverse rotation start (RY
n2
) is “0” (OFF).
(2) Operation mode changing method
CC-Link
operation mode
Change with parameter unit
Test operation
mode
A
B
Symbol Changing Description
A
CC-Link operation mode
Test operation mode
Select the test operation mode via configuration
S/W or use push button on the front panel.
B
Test operation mode
CC-Link operation mode
Deselect the test operation mode via configuration
S/W or use push button on the front panel