Specifications

10
BCN-B11127-478*
4.2.4 Communication baudrate setting
Set the transfer baudrate of CC-Link with the transfer baudrate switch (SW3) on the servo amplifier
front. The initial value is set to 156kbps.
The overall distance of the system changes with the transfer speed setting. For details, refer to the CC-
Link system master/local module user's manual.
8
0
5
1
2
3
4
9
7
6
No.
Baudrate
1
2
3
4
Not used
0 (initial value)
SW3
156kbps
5 to 9
625kbps
2.5Mbps
5Mbps
10Mbps
4.2.5 Occupied station count setting
Set the number of occupied stations with the occupied station count switch (SW1,SW2) on the servo
amplifier front. The usable I/O signals and the number of connectable units change with the set number
of occupied stations. In the initial status, the number of stations occupied is set to 1.
SW1,SW2 setting
Number of occupied stations
1 station occu
p
ied
2 stations occu
p
ied
OFF
1
2
OFF
OFF
OFF
1
2
OFF
ON
(
Initial value
)