Service manual
1-2 ELECTRICAL PARTS SPECIFICATION
MR-C375C-A , MR-C375CL-A
Model
DHS66C10RAW
Power supply
220-240V, 50Hz
Compressor
Rated input
W
Starting current
A
Rated current
A
Winding resistance
(
A
.
T
.
20
o
C
)
PTC RELAY
PTH7M330MD2
Model
5TM718MFBYY-53
Motor protector
Ambient temperature
o
C
25
Time
Sec.
16 MAX
Current
A
4.2
Running capacitor
4
µ
F
400
VAC
Capillary tube
mm.
∅
1
.
8
X
∅
0
.
6
X
2350
Dehydrant Molecular sieve
g
10
Refrigerant HFC. 134a
g
170
Defrosting timer
Control board
Defrost finish
o
C
Thermister
14
+
1
.
5
Thermal fuse
o
C
73
Defrost heater
Not equipped
Model
FBA12J12VXC
Type
DC brushless
Rate Voltage
12 VDC
Input
W
4.2 (12 VDC)
Revolution
r.p.m
2300 (12 VDC)
Model
4715JL04WS16G51
Type
DC brushless
Rate Voltage
12 VDC
Input
W
1.44 (12 VDC)
Revolution
r.p.m
1450 (12 VDC)
Vegetable case heater
W
6
Water pipe heater
W
0.9
Drain pipe heater
W
6
Freezer
Refrigerator
Dial position
ON
OFF
OPEN
SHUT
LOW
o
C
-9.2
-15.7
7.0
5.1
MID
o
C
-14.0
-20.0
4.2
2.3
HI
o
C
-16.0
-21.9
1.6
-0.2
Refrigerator
372
Ω
(
240
V
,
155
W
)
113/113.5(220/240V 50Hz)
7.78/8.55(220/240V 50Hz)
0.70/0.64(220/240V 50Hz)
18
.
4
Ω
(
Main
) /
18
.
5
Ω
(
Aux
)
Defrosting control
Deodorizing function of defrost heater
Thermistor R
Thermistor F
Fan motor
Heater
Machine
Chamber
Temperature control
3