13
Conversion Unit for SSCNET of MR-J2S-B Compatible Servo Amplifier: MR-J4-B-RJ020
Conversion Unit for SSCNET of MR-J2S-B: MR-J4-T20
Conversion Unit for SSCNET of MR-J2S-B Compatible Servo Amplifier: MR-J4-B-RJ020
Conversion Unit for SSCNET of MR-J2S-B: MR-J4-T20
TE2
TE3
TE1
Exhaust
Intake
Cooling fan
When mounting
MR-BAT6V1SET
6
6 118
130
7.5
2357.5
250
200
(60)
(38.5)
Approx. 80
(28)
132
PE
Terminal diagram
(with front cover open)
2-ø6 mounting
hole
L1 L2 L3
N- P3 P4
C
Terminal arrangement
P+ U V W
TE1
TE2
PE
L11 L21
TE3
Terminal screw size
TE1: M4
TE2: M3.5
TE3: M4
PE: M4
Mounting screw size: M5
Built-in regenerative
resistor lead terminal
fixing screw
6
300
7.5
Cooling fan
Exhaust
Intake
2-ø6 mounting hole
When mounting
MR-BAT6V1SET
200172
174
160 66
7.5 285
6
Approx. 80
TE3
TE1
TE2
PE
(101)
(38.5)
Terminal diagram
(with front cover open)
L1 L2 L3
N- P3 P4
C
Terminal arrangement
P+ U V W
TE1
TE2
PE
L11 L21
TE3
Terminal screw size
TE1: M4
TE2: M3.5
TE3: M4
PE: M4
Mounting screw size: M5
(28)
Built-in regenerative
resistor lead terminal
fixing screw
MR-J4-B-RJ020 Dimensions
(Note 1)
MR-J4-500B4-RJ020
l
MR-J4-700B-RJ020
l
MR-J4-700B4-RJ020
l
[Unit: mm]
Notes: 1. The dimensions are applicable when MR-J4-B-RJ020 and MR-J4-T20 are combined. Refer to "MR-J4-B(-RJ) Dimensions" in "MELSERVO-J4 catalog (L(NA)03058)" for
the dimensions of MR-J4-B-RJ020 servo amplifiers alone.
[Unit: mm]