Specifications
General-Purpose AC Servo
MELSERVO-J3
Drive Safety integrated AC servo amplifier
<MR-J3-S 0.1kW to 55kW>
Safety logic unit <MR-J3-D05>
The MR-J3-S Drive Safety integrated AC servo amplifier (SSCNET
Ⅲ compatible) and MR-J3-D05 safety logic unit are newly added to
the MELSERVO-J3 series.
Safety functions of the MR-J3-S and MR-J3-D05 are certified for
IEC/EN 61508 SIL 2, EN 62061 SIL CL 2 and EN ISO 13849-1 PL d
(Category 3) by a Certification Body (TÜV Rheinland).
As a safety function, MR-J3-S has an integrated Safe torque off
(STO) function. Safe stop 1 (SS1) function can be realized by
combining MR-J3-S with MR-J3-D05. These functions contribute
to improvement of safety in the user’s system, making it easy to
obtain third-party certification.
If MR-J3-B is currently used in a user’s system, it can be easily
replaced by the MR-J3-S since both of these servo amplifiers use
the same cables and connectors. Also, the MR-J3-S lineup
contains fully closed loop control system versions.
Features
• MR-J3-S and MR-J3-D05 meet IEC/EN 61508 SIL 2, EN 62061 SIL CL 2 and EN ISO 13849-1 PL d (Category 3). Only the
Safe torque off (STO)
*1
function is integrated into the MR-J3-S. The MR-J3-D05 contains both Safe stop 1 (SS1)
*1
and Safe
torque off (STO)
*1
functions.
• User’s system can satisfy stop category 0
*2
by using the Safe torque off (STO) function
*1
.
• User’s system can satisfy stop category 0 and 1
*2
by using the Safe torque off (STO) and Safe stop 1 (SS1) functions
*1
.
• Mounting, wiring and connectors of MR-J3-S are compatible with those of MR-J3-B. Thus, MR-J3-B can be easily
replaced by the MR-J3-S using the existing connections. The safety functions are accessible via the new CN8 connector on
the MR-J3-S.
*1. Refer to EN IEC 61800-5-2 for details of Safe torque off (STO) and Safe stop 1 (SS1) functions.
*2. Refer to EN IEC 60204-1 for details of stop category.
System Configurations (example of using 2 systems of STO and SS1 functions) (Note 5)
Notes: 1. For prevention of electric shock during maintenance or for protection during servo amplifier fault, be sure to connect a magnetic contacto
r
(MC) between the main power supply and L1, L2 and L3 of the servo amplifier or converter unit.
2. Connect the STO switch signal and forced stop 2 (EM2) signal in connector CN3 of the servo amplifier in addition to the connection with
the safety logic unit (MR-J3-D05).
3. Safety logic unit (MR-J3-D05) has 2 independent systems (A-axis and B-axis).
4. All safety-related components such as relays, sensors, etc., must meet the applicable safety standards.
5. Perform risk assessment and safety level certification on the entire machine/system.