Instruction manual

3 - 15
3 DESIGN
3.4 Design Checklist
At the worksite, copy the following table for use as a check sheet.
Item Sub Item Design confirmation Check
Module
selection
Motion CPU module
selection
Number of axes axes
Motion CPU module selection
Manual pulse generator pcs.
Incremental synchronous encoder pcs.
Number of I/O points points
PLC CPU module
selection
Number of I/O points points
PLC CPU module selection
Motion module
selection
Manual pulse generator pcs.
Synchronous encoder pcs.
Upper limit point points
Lower limit point points
STOP input point points
Proximity dog input point points
Speed switching input point points
Tracking enable signal point points
Q172DLX modules
Q172DEX modules
Q173DPX modules
Main base unit
selection
Motion CPU module modules
I/O module/intelligent function module installed to
main base unit
modules
Main base unit selection
Extension base unit
and extension cable
selection
Number of I/O modules/intelligent function
modules installed to extension base unit
modules
Distance between Main base unit and extension
base unit
mm
(inch)
Extension base unit selection
Extension cable selection
External
circuit design
Fail-safe circuit design
Avoidance of operation failure at power-on
Avoidance of hazard at Motion controller failure
Layout design Module layout design
Conformance with general specifications such as ambient
temperature, humidity, dust, etc.
Total power consumption of base unit
(Calculate the heating value)
W
Layout in consideration of clearances between enclosure's inside
walls, other structures and modules and heats generated by
modules within the control panel.