Instruction manual

2 - 94
2 SYSTEM CONFIGURATION
(4) Setting of the axis No. and axis select rotary switch of servo
amplifier
Axis No. is used to set the axis numbers of servo amplifiers connected to
SSCNET
connector(CN ) in the program.
The following range can be set in the Motion CPU module.
Axis No. is set for each SSCNET
(/H) line in the system setting of
MT Developer2. Axis No. is allocated and set for the setting axis number (d01 to
d16) of servo amplifier.
Axis No. setting range
Q173DSCPU
1 to 32
Q173DCPU(-S1)
Q172DSCPU 1 to 16
Q172DCPU(-S1) 1 to 8
Since the axis number (d01 to d16) of servo amplifier on the system setting
screen corresponds to axis select rotary switch (0 to F) of servo amplifier, set the
axis select switch referring to the table of next page.
Setting display of axis No.
Set the axis No. relative to axis number (dno.).
Axis select rotary switch
(Servo amplifier)
1
C
B
A
9
8
7
6
5
4
3
2
0
F
E
D
(Note): Correspondence between dno. and axis select rotary switch of servo amplifiers is shown in
the next page.