User`s manual

2 - 65
2 SYSTEM CONFIGURATION
POINTS
(1) Be sure to connect SSCNET cable with the above connector. If the
connection is mistaken, between the Motion CPU module and servo amplifier
cannot be communicated.
(2) SSCNET
connector is put a cap to protect light device inside connector from
dust. For this reason, do not remove a cap until just before connecting
SSCNET
cable. Then, when removing SSCNET cable, make sure to put a
cap.
(3) Be sure to keep a cap and the tube for protecting light code end of SSCNET
cable in a plastic bag with a zipper of SSCNET
cable to prevent them from
becoming dirty.
(4) Do not remove the SSCNET
cable while turning on the power supply of
Multiple CPU system and servo amplifier.
Do not see directly the light generated from SSCNET
connector of Motion
CPU module or servo amplifier and the end of SSCNET
cable. When the
light gets into eye, may feel something is wrong for eye. (The light source of
SSCNET
cable complies with class1 defined in JISC6802 or
IEC60825-1.)
(5) When exchanging the servo amplifier or Motion CPU module, make sure to put
a cap on SSCNET
connector. When asking repair of servo amplifier or
Motion CPU module for some troubles, make also sure to put a cap on
SSCNET
connector. When the connector is not put a cap, the light device
may be damaged at the transit. In this case, exchange and repair of light
device is required.
(3) Cable specifications
(a) MR-J3BUS M
Model name
Item
MR-J3BUS015M MR-J3BUS03M MR-J3BUS05M MR-J3BUS1M MR-J3BUS3M
Cable length [m(ft.)] 0.15(0.49) 0.3(0.98) 0.5(1.64) 1(3.28) 3(9.84)
(b) MR-J3BUS M-A
Model name
Item
MR-J3BUS5M-A MR-J3BUS10M-A MR-J3BUS20M-A
Cable length [m(ft.)] 5(16.40) 10(32.81) 20(65.62)
(c) MR-J3BUS M-B
Model name
Item
MR-J3BUS30M-B MR-J3BUS40M-B MR-J3BUS50M-B
Cable length [m(ft.)] 30(98.43) 40(131.23) 50(164.04)