User`s manual
2 - 52
2 SYSTEM CONFIGURATION
2.4.6 Q173DPX Manual pulse generator interface module
Q173DPX receive external signals required for Manual pulse generator and
Incremental synchronous encoder (Voltage-output/Open collector type/Differential-
output type).
(1) Q173DPX name of parts
TREN
Q173DPX
PULSER
Q173DPX
PLS.A
3
2
1
2)
4)
1)
3)
3
PLS.B
2
1
3
2
1
5)
7)
123456
KSD06S
ON
6)
No.
Name Application
1) Module fixing hook
Hook used to fix the module to the base unit.
(Single-motion installation)
Display the input status from the external equipment.
LED Details
PLS.A 1 to 3
PLS.B 1 to 3
Display for input signal status of
manual pulse generator/incremental
synchronous encoder phases A, B
TREN 1 to 3
Display for signal status of tracking
enable.
2) Mode judging LED
The manual pulse generator/incremental synchronous
encoder phases A, B and tracking enable signal does not
turn ON without setting Q173DPX in the system setting.
3) PULSER connector
Input connector of the Manual pulse generator/Incremental
synchronous encoder.
4) Module loading lever Used to install the module to the base unit.
5)
Module fixing screw
hole
Hole for the screw used to fix to the base unit
(M3×12 screw : Purchase from the other supplier)