User`s manual
4 - 24
4 INSTALLATION AND WIRING
(4) Twisting
If the SSCNET cable is twisted, it will become the same stress added condition
as when local lateral pressure or bend is added. Consequently, transmission loss
increases, and the breakage of optical fiber may occur at worst.
(5) Disposal
When incinerating optical cable (cord) used for SSCNET , hydrogen fluoride gas
or hydrogen chloride gas which is corrosive and harmful may be generated. For
disposal of optical fiber, request for specialized industrial waste disposal services
who has incineration facility for disposing hydrogen fluoride gas or hydrogen
chloride gas.
(6) Wiring process of SSCNET cable
Put the SSCNET cable in the duct or fix the cable at the closest part to the
Motion CPU module with bundle material in order to prevent SSCNET
cable
from putting its own weight on SSCNET
connector.
Leave the following space for wiring.
•
Putting in the duct
Top of panel or wiring duct
Base unit
I/O11
I/O11
Q312DB
QX40
0 1 2 3 4 5 6 7
8 9 A B C D E F
SY.ENC1
Q172DEX
Q172DEX
2
1
TREN
SY.ENC
2
1
Q173DPX
PULSER
Q173DPX
PLS. A
3
2
1
PLS. B
3
2
1
TREN
3
2
1
MELSEC
Q61 P
POWER
PULL
Q03DCPU
US E R
MODE
RUN
ERR.
BAT.
BOOT
PULL
USB
RS -232
QX40
0 1 2 3 4 5 6 7
8 9 A B C D E F
BAT
FRON T
CN2 CN1
EMI
CAUT I ON
STOP RUN
12
SW
Q173DCPU
Motion CPU module
Motion CPU module
Doo
r
100mm
(3.94inch)
or more
123.5mm
(4.86inch)
Panel
40mm
(1.58inch)
or more
100mm
(3.94inch)
or more
5mm(0.20inch)
or more
(Note-1)
5mm(0.20inch)
or more
(Note-1) : 20mm (0.79 inch) or more when the adjacent module is not removed and the extension cable is connected.