Table 1.2 Special register list (Continued)
No. Name Meaning Details
Set by
(When set)
Remark
SD395 Multiple CPU No. Multiple CPU No. CPU No. of the self CPU is stored. S (Initial processing)
SD500
SD501
Real mode axis
information
register
Real mode axis
information register
• The information (Real mode axis: 0/Except real mode axis: 1) used as a real
mode axis at the time of switching from real mode to virtual mode is stored.
SD500 : b0 to b15 (Axis 1 to 16)
SD501 : b0 to b15 (Axis 17 to 32)
• The real mode axis information does not change at the time of switching from
virtual mode to real mode
S (At virtual mode
transition)
SD502
SD503
Servo amplifier
loading
information
Servo amplifier
loading information
• The loading status (loading: 1/non-loading: 0) of the servo amplifier checked
in initial process, and stored as the bit data.
SD502 : b0 to b15 (Axis 1 to 16)
SD503 : b0 to b15 (Axis 17 to 32)
• The axis which turned from non-loading to loading status after power-on is
handled as loaded. (However, the axis which turned from loading to non-
loading status remains as loaded.)
S (Initial processing)
SD504
SD505
SD506
Real mode/virtual
mode switching
error information
Real mode /virtual
mode switching
error code
When a mode switching error occurs in real-to-virtual or virtual-to-real
mode switching, or a mode continuation error occurs in the virtual mode, its
error information is stored.
S (Occur an error)
• This signal is used to temporarily suspend SSCNET communication while
servo amplifiers and/or SSCNET
cables after Axis 1 are exchanged with the
power supply ON in a Multiple CPU system.
SD508 stores the command status for "accept waiting" or "execute waiting"
during this process.
0 : Connect/disconnect command accept waiting
-1 : Connect/disconnect execute waiting
SD508
Connect/
Disconnect
(Status)
Connect/
disconnect of
SSCNET
-2 Connect/disconnect executing
SD510
SD511
Test mode
request error
It is operating in
requirement error
occurrence of the
test mode, axis
information
• Each axis is stopping: 0/Operating: 1, information is stored as a bit data.
SD510 : b0 to b15 (Axis 1 to Axis 16)
SD511 : b0 to b15 (Axis 17 to Axis 32)
S (Main processing)
SD512
Motion CPU
WDT error cause
Error meaning of
WDT error occurs
• The following error codes are stored in SD512.
1: S/W fault 1
2: Operation cycle over
3: Q bus WDT error
4: WDT error
201 to 215: Q bus H/W fault
250 to 253: Servo amplifier interface H/W fault
300: S/W fault 3
301: 15 CPSTART instructions of 8 or more points were started
simultaneously.
303: S/W fault 4
SD513
SD514
SD515
Manual pulse
generator axis
setting error
Manual pulse
generator axis
setting error
information
Contents of the manual pulse generator axis setting error is stored when the
manual pulse generator axis setting error flag (SM513) turn on.
(Normal: 0/Setting error: 1)
SD513 : The manual pulse generator axis setting error is stored in b0 to b2
(P1 to P3).
The smoothing magnification setting is stored in b3 to b5 (P1 to P3).
SD514 : One pulse input magnification setting error is stored in b0 to b15
(axis 1 to axis 16).
SD515 : One pulse input magnification setting error is stored in b0 to b15
(axis 17 to axis 32).
SD516
Error program
No.
Error program No.
of servo program
When the servo program setting error flag (SM516) turns on, the erroneous
servo program No. will be stored.
SD517
Error item
information
Error code of servo
program
When the servo program setting error flag (SM516) turns on, the error code
corresponding to the erroneous setting item will be stored.
S (Occur an error)
SD520 Scan time
Scan time
(1ms units)
• Main cycle is stored in the unit 1ms.
Setting range (0 to 65535[ms])
SD521
Maximum scan
time
Maximum scan
time (1ms units)
• The maximum value of the main cycle is stored in the unit 1ms.
Setting range (0 to 65535[ms])