Specifications

Mounting and wiring SSCNET III connection
3 - 12
3.3.3 Connection between the Q172DCPU and servo amplifiers
Chose the right SSCNET III cable type in tab. 3-5 depending on the cable length for your system
configuration.
Attach a cap to the SSCNET III connectors of the system not being used.
Fig. 3-11: SSCNET III connection method with Q172DCPU
NOTE
If the connectors CN1A und CN1B are mixed up at the servo amplifiers, no communication is possible.
Q172DCPU Motion CPU module
Servo amplifier Servo amplifier
Cap
CN1A
CN1B
CN1A
CN1B
CN1