Specifications
SSCNET III connection Mounting and wiring
Motion controller Q170MCPU/ Q172DCPU/ Q173DCPU 3 - 11
3.3 SSCNET III connection
3.3.1 SSCNET III cable
The cables in the following table are applicable for the connection between the Q170MCPU/QD-Mo-
tion controllers and the servo amplifier MR-J3-첸B and between the servo amplifiers MR-J3-첸B.
3.3.2 Connection between the Q170MCPU and servo amplifiers
햲
Chose the right SSCNET III cable type in tab. 3-5 depending on the cable length for your system
configuration.
햳
Attach a cap to the SSCNET III connectors of the system not being used.
Cable
Symbol for cable length (첸)
0,15 m 0,3 m 0,5 m 1 m 3 m 5 m 10 m 20 m 30 m 40 m 50 m
MR-J3BUS첸M
0150305 1 3 ——————
MR-J3BUS첸M-A
————— 5 1020———
MR-J3BUS첸M-B
————————304050
Tab. 3-5: SSCNET III cable identification
Fig. 3-10: SSCNET III connection method with Q170MCPU
NOTE
If the connectors CN1A und CN1B are mixed up at the servo amplifiers, no communication is possible.
Q170MCPU
햲
햲
Servo amplifier Servo amplifier
Cap
햳
CN1A
CN1B
CN1A
CN1B
CN1