Instruction manual

APP - 27
A
PPENDICES
Table 1.12 Servo error (2000 to 2899) list (Continued)
Error cause Error
code
Name Description
Error check
Error
processing
Corrective action
• Short occurred in servomotor power (U,
V, W).
• Correct the wiring.
• Transistor (IPM) of the servo amplifier
faulty.
[Checking method]
Servo error [2032] occurs if power is
switched on after U, V and W are
disconnected.
Replace the servo amplifier.
• Ground fault occurred in servomotor
power (U, V, W).
• Correct the wiring.
2032 Overcurrent
• External noise caused the overcurrent
detection circuit to misoperate.
• Take noise suppression
measures.
• Lead of built-in regenerative brake
resistor or regenerative brake option is
open or disconnected.
• Replace the lead.
• Connect correctly.
• Regenerative transistor faulty. • Replace the servo amplifier.
• Wire breakage of built-in regenerative
brake resistor or regenerative brake
option.
• For wire breakage of built-in
regenerative brake resistor,
replace the servo amplifier.
• For wire breakage of
regenerative brake option,
replace the regenerative brake
option.
• Capacity of built-in regenerative brake
resistor or regenerative brake option is
insufficient.
• Add regenerative brake option or
increase capacity.
• Power supply voltage is high. • Review the power supply.
2033 Overvoltage
• Ground fault occurred in servomotor
power (U, V, W).
• Correct the wiring.
2034
Communica-
tions error
Data received from the Motion CPU
faulty.
• Check the connection of
SSCNET
cable.
• Check if there is a disconnection
in the SSCNET
cable.
There is excessive variation in the
position commands and command
speed is too high from the Motion CPU.
• Check the command speed and
the number of pulses per
revolution/travel value per
revolution of the fixed
parameters.
• Noise entered the commands from the
Motion CPU.
• Check the connection of
SSCNET
cable.
• Check if there is a disconnection
in the SSCNET
cable.
Check if any relays or solenoids
are operating in the vicinity.
2035
Command
frequency error
Motion CPU failure Replace the Motion CPU.
2036
Transmission
error
Fault in communication with the Motion
CPU.
Any time during
operation
Immediate
stop
• Check the connection of
SSCNET
cable.
• Check if there is a disconnection
in the SSCNET
cable.