Instruction manual

APP - 14
A
PPENDICES
Table 1.5 Positioning control error (200 to 299) list (Continued)
Control mode
Error
code
Positioning
Fixed-pitch feed
Speed
Speed/position switching
Speed switching
Constant-speed
JOG
Manual pulse generator
Home position return
Position follow-up control
OSC
Speed control with
fixed position stop
Error cause
Error
processing
Corrective action
207
• The feed current value
exceeded the stroke limit
range during positioning
control. Only the axis
exceed the stroke limit
range is stored at the
circular/helical interpolation.
All interpolation axes are
stored in the linear
interpolation.
208
• The feed current value of
another axis exceeded the
stroke limit value during the
circular/helical interpolation
control or simultaneous
manual pulse generator
operation. (For detection of
other axis errors).
Correct the stroke limit range or
travel value setting so that
positioning control is within the
range of the stroke limit.
209
• An overrun occurred
because the setting travel
value is less than the
deceleration distance at the
speed/position switching
(CHANGE) signal input
during speed/position
switching control, or at the
proximity dog signal input
during home position return
of count type.
• Set the speed setting so that
overrun does not occur.
• Set the travel value so that
overrun does not occur.
210
• The setting travel value
exceeded the stroke limit
range at the speed/position
switching (CHANGE) signal
input during the speed/
position switching control.
Correct the stroke limit range or
setting travel value so that
positioning control is within the
range of stroke limit.
211
• During positioning control,
an overrun occurred
because the deceleration
distance for the output
speed is not attained at the
point where the final
positioning address was
detected.
Decelera-
tion stop
• Set the speed setting so that
overrun does not occur.
• Set the travel value so that
overrun does not occur.
214
• The manual pulse generator
was enabled during the start
of the applicable axis, the
manual pulse generator
operation was executed.
Manual
pulse
generator
input is
ignored
until the
axis stops.
• Execute the manual pulse
generator operation after the
applicable axis stopped.