User Guide
Specications are subject to change without notice. © 2017 Mitsubishi Electric US, Inc.
MXZ-2C20NAHZ2 OPERATIONAL PERFORMANCE
NON-DUCTED:
# of
indoor
unit
Total Nominal
Capacity
(x1000 Btu/h)
Total Indoor Unit
Capacity (Btu/h)
Operational Performance for
Indoor Unit Combinations
(Unit A + Unit B + Unit C)
Cooling Capacity Range (Btu/h)
Heating Capacity Range (Btu/h)
Unit A Unit B Unit C
1 6
6,000
6
6,000 - -
7,400 7,400 - -
1 9
9,000
9
9,000 - -
11,000 11,000 - -
1 12
12,000
12
12,000 - -
14,400 14,400 - -
1 15
14,000
15
14,000 - -
18,000 18,000 - -
2 12
12,000
6 + 6
6,000 6,000 -
14,800 7,400 7,400 -
2 15
15,000
6 + 9
6,000 9,000 -
18,400 7,400 11,000 -
2 18
18,000
6 + 12
6,000 12,000 -
22,000 7,500 14,500 -
2 18
18,000
9 + 9
9,000 9,000 -
22,000 11,000 11,000 -
2 21
20,000
6 + 15
6,000 14,000 -
22,000 6,400 15,600 -
2 21
20,000
9 + 12
8,600 11,400 -
22,000 9,500 12,500 -
2 24
20,000
9 + 15
7,800 12,200 -
22,000 8,300 13,700 -
2 24
20,000
12 + 12
10,000 10,000 -
22,000 11,000 11,000 -
DUCTED:
# of
indoor
unit
Total Nominal
Capacity
(x1000 Btu/h)
Total Indoor Unit
Capacity (Btu/h)
Operational Performance for
Indoor Unit Combinations
(Unit A + Unit B + Unit C)
Cooling Capacity Range (Btu/h)
Heating Capacity Range (Btu/h)
Unit A Unit B Unit C
1 9
9,000
9
9,000 - -
10,900 10,900 - -
1 12
12,000
12
12,000 - -
13,600 13,600 - -
1 15
15,000
15
15,000 - -
18,000 18,000 - -
2 18
18,000
9 + 9
9,000 9,000 -
21,800 10,900 10,900 -
2 21
20,000
9 + 12
8,600 11,400 -
22,000 9,800 12,200 -
2 24
20,000
9 + 15
7,500 12,500 -
22,000 8,300 13,700 -
2 24
20,000
12 + 12
10,000 10,000 -
22,000 11,000 11,000 -