Specifications
Table Of Contents
- Front Cover
- Manual number
- Guideline of safety
- Table of Contents
- 1. Communication Capabilities
- 2. SMS/SMR/CD Functions and the Modem Setting
- 3. Remote Access
- 4. SMS Messaging Diagnostics
- 5. Computer Link - Dedicated Protocol
- 6. AL-PCS/WIN-E Settings for Dedicated Protocol
- 7. The Command String
- 8. Dedicated Protocol Error Diagnostics
- Back Cover

α
2
Simple Application Controllers
SMS/SMR/CD Functions and the Modem Setting 2
2 - 16
Table 2.5: Phone numbers and Outputs
E) Maintenance
If this check box is checked maintenance mode will be selected.
F) Retentive
Check the "Retentive" checkbox is store the output value even after a Power cut.
G) Number of RING before call detect
Range: 1-20
Cautions for the use of both Call Detec and remote access
- When it remotely accesses from the same telephone number for Call Detect, CD and FB
operate.
Cautions for misoperations
- CD FB operates also by a misoperation of a telephone.
In order to avoid serious injury and the machine damage caused by unintended CD FB
operation, provide safety devices as countermeasure.
FB number Caller's phone number FB Output
+49 21 02 12 34 56 7 +49 21 02 12 34 56 7 changed
+49 21 02 12 34 56 7 +49 21 02 12 34 56 8 no change
+49 21 02 12 34 56 7 +49 21 02 12 34 no change
+49 21 02 12 34 56 7 +49 21 02 12 34 56 78 no change
+49 21 02 12 34 56 7* +49 21 02 12 34 56 7 no change
+49 21 02 12 34 56 +49 21 02 12 34 56 7 no change
+49 21 02 12 34 56 * +49 21 02 12 34 56 7 changed
+49 21 02 12 3* +49 21 02 12 34 56 7 changed
+49 21 02 12 3* +49 21 02 12 34 56 8 changed
+49 21 02 12 3* +49 21 02 12 34 56 78 changed
* Any phone number changed
+* Any international phone number changed