Installation manual
4
Wall
Outdoor
side
2-2. HOLE DRILLING
1) Determine the wall hole position.
2) Drill a dia. 65 mm hole (dia. 75 mm for KA50). The outdoor side
should be 5 to 7 mm lower than the indoor side.
3) Insert wall hole sleeve (C).
2-1. FIXING OF INDOOR UNIT MOUNTING BRACKET
• Findastructuralmaterial(suchasastud)inthewallandxbracket(7)horizontallywithxingscrews(8).
• Topreventbracket(7)fromvibrating,besuretoinstallthexingscrewsintheholesindicatedby[->]intheillustration.Foraddedsupport,xingscrews
may also be installed in other holes.
2. INDOOR UNIT INSTALLATION
FOR RIGHT DOWNWARD OR LEFT DOWN-
WARD PIPING
(Thefollowinggureisaviewofthebottomof
the indoor unit from above.)
FOR REAR OR LEFT-REAR PIPING
(Thefollowinggureisafrontview
of the indoor unit installation location.)
FOR LEFT PIPING FOR RIGHT PIPING
When the unit is
installed on the wall.
When the unit is
installedontheoor.
HOLE POSITIONS
ø65mm (KA25/35)
ø75mm (KA50)
5 - 7 mm
2-3. INDOOR UNIT PREPARATION
Remove the front panel of the indoor unit.
1) Push the 2 locations marked “PUSH” on the upper part of the front
grille until a “click” is heard.
2) Open the front grille toward you.
3) Remove the 2 screws.
4) Grasp the rear horizontal vane at the upper air outlet, and open it.
5) Push the 3 locations on the top of the front panel, and then pull the
upper part of the front panel toward you.
6) Remove the front panel while lifting it up (slightly).
* The front panel can be removed without opening the damper of the
lower air outlet.
*
Do not open the damper
of the lower air outlet.
Front horizontal
vane
Rear horizontal
vane
Front panel
Front panel
Push
Indoor unit
Indoor unit
JG79A144H05.indd 4 2011/06/22 16:01:19