Specifications
4
BCN-B11127-479*
2) The following configuration uses external I/O signals. The external input signals are used to
control all signals (devices) that response delay is less than 15msec.
3) Function list
Contents Description
Operation specification - Positioning up to 31 point via point block #
Position command input
- Setting at point block
- Setting range for positioning: +/- 1 [um] to +/- 999.999 [um]
Speed command input
- Setting at point block
- Set at the point block for acc. / dec. time
- Parameter # 14 is for S-Curve acc. / dec. time constant
Point block # input
System - Absolute value command with sign or incremental value command
Operation specification - Positioning via RS-422(232C) communication
Position command input
- Setting via RS-422(232C) communication
- Setting range for positioning : +/- 1 [um] to +/- 999.999 [um]
Speed command input
- Setting via RS-422(232C) communication
- Set the acc. / dec. time via RS-422(232C) communication
- Parameter # 14 is for S-Curve acc. / dec. time constant
Command type
Position data input
System - Absolute value command with sign or incremental value command
Automatic mode
- Select the required ones from among 31 preset point blocks and
perform operation in accordance with the set value
(Position block # input, Position data input)
Manual mode JOG
- Jogging operation among preset jog speed via RS-422(232C)
communication or external input
Operation mode
Manual zeroing Stopper type zeroing
- Stopper type zeroing
Capable set the zero address at parameter setting
Function on positioning control
- Absolute position detection system
- Backlash compensation
- External stroke limit function
- Software stroke limit function
- Teaching function
- Roll feeding function (equivalent)
Servo amplifie
r
External I/O
signals
Power supply
3-phase 200VAC
or single-phase
230VAC
Servo moto
r
CN1A CN1B
CN2 CN3