Specifications
40
BCN-B11127-479*
Class No.
Symbol
Name and Function
Initial
Value
Unit Setting Range
57 *OP8 Function selection 8
Used to select the protocol of serial communication.
0000
0000h
to
1112h
58 *OP9 Function selection 9
Use to select the command pulse rotation direction, encoder output pulse
direction and encoder pulse output setting.
0000
0000h
to
1101h
59 *OPA Function selection A
Alarm code output function selection
0000
0000h
to
0211h
Expansion parameters
60 For manufacture setting 0000
0
0
0
Alarm code output
0: Invalid
1: Valid
0 0
Protocol checksum selection
0: Yes (checksum added)
1: No (checksum not added)
Protocol checksum selection
0: With station numbers
1: No station numbers
0
0
1
CCW
CW
CW
C
C
W
Servo motor rotation direction changing
Changes the servo motor rotation
direction for the input pulse train.
Set value
Servo motor rotation direction
At forward rotation
pulse input (Note)
A
t reverse rotation
pulse input (Note)
Encoder pulse output phase changing
Changes the phases of A, B-phase encoder pulses output .
Encoder output pulse setting selection (refer to parameter No. 27)
0: Output pulse setting
1: Division ratio setting
Servo motor rotation direction
Set value
CCW CW
0
1
A
phase
B phase
A
phase
B phase
A
phase
B phase
A
phase
B phase