Specifications
35
BCN-B11127-479*
Class No. Symbol Name and Function Initial Value Unit Setting Range
18 *DMD Status display selection
Used to select the status display shown at power-on .
0000 0000h
to
1F1Fh
Basic parameters
19 *BLK Parameter block
Used to select the reference and write ranges of the parameters.
Parameter No.
Set Value Operation
#00
to
#18
#19
#20
to
#53
#54
to
#90
Reference { { × ×
0000
(Initial value)
Write { { × ×
Reference × { × ×
000A
Write × { × ×
Reference { { { ×
000B
Write { { × ×
Reference { { { ×
000C
Write { { { ×
Reference { { { {
000E
Write { { { {
0000 0000h
to
FFFFh
Status display shown at power-on
00: Current position
01: Command position
02: Command remaining distance
03: Point table No.
04: Cumulative feedback pulses
05: Motor speed
06: Droop pulses
07: Override voltage
08: Limiting torque voltage
09: Regenerative load ratio
0A: Effective load ratio
0B: Peak load ratio
0C: Instantaneous torque
0D: Within one-revolution position (low)
0E: Within one-revolution position (high)
0F: ABS counter
10: Load inertia moment ratio
11: Bus voltage
0