Specifications
28
BCN-B11127-479*
7. Parameters
For any parameter whose symbol is preceded by *, set the parameter value and switch power off once,
then switch it on again to make that parameter setting valid.
For details of the parameters, refer to the corresponding items.
(1) Item list
Class No. Symbol Name and Function Initial Value Unit
Customer
Setting
0 *STY Control mode, regenerative brake option selection 0010
1 *FTY Feeding function selection 0000
2 *OP1 Function selection 1 0002
3 AUT Auto tuning 0105
4 *CMX Electronic gear numerator 1
5 *CDV Electronic gear denominator 1
6 INP Movement completion output range 100 pulse
7 PG1 Position loop gain 1 36 rad/s
8 ZTY Zeroing type 0013
9 ZRF Zeroing speed 500 r/min
10 CRF Creep speed 10 r/min
11 ZST Zero shift distance 0 Um
12 CRP Rough match output range 0 10
STM
m
13 JOG JOG speed 100 r/min
14 *STC S-Curve acceleration/deceleration time constant 0 Ms
15 *SNO Station number setting 0 station
16 *BPS Alarm history clear 0000
17 MOD For manufacture setting 0100
18 *DMD Status display selection 0000
Basic parameters
19 *BLK Parameter block 0000