Specifications
15
BCN-B11127-479*
(4) Device setting of control mode
Automatic operation Operation mode
Signal
Absolute command
Incremental
command
Manual
drive
Manual
zeroing
Automatic/Manual
MD0
ON ON OFF ON
Point block No.
DI0
to
DI4
1 to 31 1 to 31 0
Forward rotation start
ST1
ON
(FWD. JOG)
Reverse rotation start
ST2
ON
(REV. JOG)
Note: The start signal will respond within 3 ms.
Servo motor will be stopped and cleared moving remain distance when Automatic/Manual signal
changed in positioning.
5ms 5ms
5ms
5ms