Specifications
3– 4
3.WIRING
(2) Signals
(3) How to use the control circuit terminal block (Phoenix Contact make)
1) Termination of the cables
Solid wire: After the sheath has been stripped,
the cable can be used as it is. (Cable
size: 0.2 to 2.5mm
2
)
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this
time, take care to avoid a short caused by the loose wires of the core
and the adjacent pole. Do not solder the core as it may cause a con-
tact fault. (Cable size: 0.2 to 2.5mm
2
)
Alternatively, a bar terminal may be used to put the wires together.
(Phoenix Contact make)
Approx. 10mm
Bar terminal for 1 cable
(Bar terminal ferrule with insulation sleeve)
Bar terminal for 2 cables
(Twin ferrule with insulation sleeve)
Symbol Signal Description
L1, L2, L3
Main circuit power supply
Main circuit power input terminals
Supply L1, L2 and L3 with the following power:
For single-phase 230VAC, connect the power supply to L1/L2
and leave L3 open.
Servo amplifier
MR-J2-10A
to 70A
MR-J2-100A
to 350A
MR-J2-10A1
to 40A1
Power supply
Note: Cannot be used for combination with the servo motor HC-SF52.
L1•L2•L3
L1•L2
L1•L2
3-phase 200 to 230VAC, 50/60Hz
(Note) Single-phase 230VAC, 50/60Hz
Single-phase 100 to 120VAC, 50/60Hz
L11, L21
Control circuit power supply
Control circuit power input terminals
Supply L11 and L21 with the following power:
L11 and L21 should be in phase with L1 and L2, respectively.
P, C, D Regenerative brake option
U, V, W
Servo motor output
Servo motor power output terminals
Connect to the servo motor power supply terminals (U, V, W).
N
Do not connect.
Protective earth (PE)
Ground terminal
Connect this terminal to the protective earth (PE) terminals
of the servo motor and control box for grounding.
Regenerative brake option connection terminals
C and D are factory-connected.
When using the regenerative brake option, always remove
wiring from across P-D and connect the regenerative brake
option across P-C.
Servo amplifier
MR-J2-10A
to 350A
MR-J2-10A1
to 40A1
Power supply
L11•L21
L11•L21
Single-phase 200 to 230VAC, 50/60Hz
Single-phase 100 to 120VAC, 50/60Hz
Cable Size
Bar Terminal Type
Crimping
Tool
[mm ]
2
AWG
For 1 cable For 2 cables
0.25 24
20
18
18
16
14
0.5
0.75
1
1.5
2.5
Al0.25-6YE
Al0.25-8YE
Al-TWIN2 0.75-8GY
Al-TWIN2
0.75-10GY
Al-TWIN2 1-8RD
Al-TWIN2 1-10RD
Al-TWIN2 1.5-8BK
Al-TWIN2 1.5-12BK
Al-TWIN2 2.5-10BU
Al-TWIN2 2.5-13BU
Al0.5-6WH
Al0.5-8WH
Al0.75-6GY
Al0.75-8GY
Al1-6RD
Al1-8RD
Al1.5-6BK
Al1.5-8BK
Al2.5-8BU
Al2.5-8BU-1000
CRIMPFOX-UD6