Specifications

2. OPERATION
2
2 47
44 *DI3 Input signal selection 3 (CN1B-pin 14): 0222 0000h
to
0999h
P S T
45 *DI4 Input signal selection 4 (CN1A-pin 8): 0665 0000h
to
0999h
P S T
46 *DI5 Input signal selection 5 (CN1B-pin 7): 0770 0000h
to
0999h
P S T
Allows any input signal to be assigned to CN1B-pin 14.
The assignable signals and setting method are the
same as in input signal selection 2 (parameter No. 43).
Allows any input signal to be assigned to CN1A-pin 8.
The assignable signals and setting method are the
same as in input signal selection 2 (parameter No. 43).
Allows any input signal to be assigned to CN1B-pin 7.
The assignable signals and setting method are the
same as in input signal selection 2 (parameter No. 43).
Class No.
Symbol
Initial
Value
Unit
Setting
Range
Control
Mode
Name and Function
Expansion parameters
Position
control mode
Torque control mode
Speed control
mode
Input signals of
CN1B-pin 14
selected.
0
This parameter is unavailable
when
parameter No. 42 is set to
assign the
control change signal
(LOP) to CN1 A-pin 8.
MEMORANDUM
This parameter is unavailable
when
parameter No. 42 is set to
assign the
control change signal
(LOP) to CN1B-pin 14.
MEMORANDUM
MEMORANDUM
Position
control mode
Torque control mode
Speed control
mode
Input signals of
CN1A-pin 8
selected.
0
This parameter is unavailable
when
parameter No. 42 is set to
assign the
control change signal
(LOP) to CN1 B-pin 7.
Position
control mode
Torque control mode
Speed control
mode
Input signals of
CN1B-pin 7
selected.
0