Specifications

2. OPERATION
2
2 37
14
TQC
Torque command time constant:
Used to set the constant of a low pass filter in response
to the torque command.
0
0 to 20000
T
15
For manufacturer setting
Must not be change.
0
ms
16 *BPS 0000 0000h
to
0011h
P S T
Communication baudrate selection, alarm history clear:
Used to select the communication baudrate for use of
the set-up software and to clear the alarm history.
Selection of baudrate for RS-232C
0: 9600 [bps]
1: 19200 [bps]
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made
valid, the alarm history is cleared
at next power-on. After the alarm
history is cleared, the setting is
automatically made invalid (reset to 0).
0
Torque
Torque command
After
filtered
TQC TQC
TQC: Torque command time constant
Time
0
Class No.
Symbol
Initial
Value
Unit
Setting
Range
Control
Mode
Name and Function
Basic parameters