Specifications
2
2. OPERATION
2– 29
2) 5-digit parameter
The following example shows the operation procedure performed to change the electronic
gear denominator (parameter No. 4) into "12345":
Call the display screen shown after power-on.
To the next parameter
The screen flickers.
• • • •• • • •
The set value is entered.
• • •• • •
Fifth digit setting
Lower 4 digits setting
Press MODE three times. Select parameter No. 4 with UP / DOWN .
Press SET once.
Press MODE once.
Press SET once.
Change the set value
with UP / DOWN.
Press SET once.
Press UP or DOWN.