Specifications
9.CHARACTERISTICS
9– 12
Use the dynamic brake at the load inertia
moment indicated on the right. If the load
inertia moment is higher than this value, the
built-in dynamic brake may burn. If there is
a possibility that the load inertia moment
may exceed, contact Mitsubishi.
Servo Amplifier
Load Inertia Moment
Ratio [times]
MR—J2—10A
to
30
16
MR—J2—200A
MR—J2—10A1
to
MR—J2—40A1
MR—J2—350A
Top
Bottom
Servo motor
Measuring position
Servo Motor Vibration
Measurin
g
Conditions
The vibration rank of the servo motor is V-10 at the rated speed. Measure vibration in the following
position with the servo motor installed as shown below.
9-5 Vibration rank