Specifications

6 23
6
6. OPTIONS AND AUXILIARY EQUIPMENT
Strip the cable sheath of
the clamped area.
Cutter
Cable
Cable clamp
(A, B)
Cable
Earth plate
External conductor
Clamp section diagram
40 (1.57)
(3) Cable clamp fitting (AERSBAN- SET)
Generally, the earth of the shielded cable may
only be connected to the connector's SD ter-
minal. However, the effect can be increased
by directly connecting the cable to an earth
plate as shown below.
Install the earth plate near the servo ampli-
fier for the encoder cable. Peel part of the
cable sheath to expose the external conduc-
tor, and press that part against the earth plate
with the cable clamp. If the cable is thin,
clamp several cables in a bunch.
The clamp comes as a set with the earth
plate.
Outline drawing
Earth plate Clamp section diagram
Note: Screw hole for grounding. Connect it to
the earth plate of the control box.
Type
AERSBAN DSET
AERSBAN ESET
A
100
(3.94)
70
(2.76)
B
86
(3.39)
56
(2.20)
C
30
(1.18)
Accessory Fittings
clamp A: 2pcs.
clamp B: 1pc.
Clamp Fitting
A
B
L
70
(2.76)
45
(1.77)
24
-0.2
-0
(Note) M4 screw
B±0.3 (0.01)
7 (0.28)
11 (0.43)
3 (0.12)
6 (0.24)
C
A
6
(0.24)
22 (0.87)
17.5 (0.69)
35 (1.38)
35 (1.38)
2 ø5(0.20) hole
Installation hole
L or less 10 (0.39)
30 (1.18)
24
+0.3
0
0.940
(0.940)
[Unit: mm]