Specifications
6– 18
6. OPTIONS AND AUXILIARY EQUIPMENT
6-2-3 Power factor improving reactors
Servo amplifier Model Model
MR–J2–10(1)•20A(1)
MR–J2–40A(1)
MR–J2–60A•70A
MR–J2–100A
MR–J2–200A
MR–J2–350A
FR–BAL–0.4K
FR–BAL–0.75K
FR–BAL–1.5K
FR–BAL–2.2K
FR–BAL–3.7K
FR–BAL–7.5K
Dimensions [mm (in)]
Weight
[kg(lb)]
2
(4.4)
3
(6.6)
4
(8.8)
6
(13.2)
8.5
(18.7)
14.5
(32.0)
D
120
(4.72)
120
(4.72)
145
(5.71)
145
(5.71)
200
(7.87)
200
(7.87)
E
45
(1.77)
57
(2.24)
55
(2.17)
75
(2.95)
70
(2.76)
100
(3.94)
F
M4
M4
M4
M4
M5
M5
C
120
(4.72)
120
(4.72)
145
(5.71)
145
(5.71)
200
(7.87)
205
(8.07)
B
64
(2.25)
74
(2.91)
76
(2.99)
96
(3.78)
95
(3.74)
125
(4.92)
A
135
(5.31)
135
(5.31)
160
(6.30)
160
(6.30)
220
(8.66)
220
(8.66)
Outline drawing and connection diagram of the power factor improving reactor
Single-phase AC
230V
Servo amplifier
MR – J2 – A
NFB FR – BAL
R
S
T
X
L
1
L
2
L
3
Y
Z
Single-phase AC
100~120V
Servo amplifier
MR – J2 – A1
NFB FR – BAL
R
S
T
X
L
1
L
2
Y
Z
Servo amplifier
MR – J2 – A
Single-phase AC
200~230V
NFB FR – BAL
R
S
T
X
L
1
L
2
L
3
Y
Z
E
D
RXS YTZ
A
B or less
F mounting
screw
Terminal
block
Specification
number
Serial
number
C or less
6-2-4 Relays
The following relays should be used with the interfaces:
Interface
Relay used especially for switching on-off analog input com-
mand and digital input command (interface DI-1) signals
Relay used for digital output signals (interface DO-1)
To prevent defective contacts, use a relay for small signal
(twin contacts).
(Ex.) OMRON: type G2A, MY
Small relay with 12VDC or 24VDC of 40mA or less
(Ex.) OMRON: type MY
Selection Example
The input power factor is improved to about 90%. For use with a single-phase power supply, it may
be slightly lower than 90%.