Specifications

3.WIRING
3 36
WARNING
1. Connect the wires to the correct phase terminals (U, V, W) of the servo
amplifier and servo motor. Otherwise, the servo motor will operate
improperly.
2. Do not connect AC power supply directly to the servo motor. Other-
wise, a fault may occur.
Insulate the connections of the power supply terminals to prevent an elec-
tric shock.
(2) For grounding, connect the earth cable of the servo motor to the
protective earth (PE) terminal of the servo amplifier and connect
the ground cable of the servo amplifier to the earth via the pro-
tective earth of the control box.
Do not connect them directly to the protective earth of the con-
trol panel.
(3) Do not share the 24VDC power supply between the interface and
electromagnetic brake. Always use the power supply designed
exclusively for the electromagnetic brake.
(1) Wind an insulation tape around the connection several times.For the EN Standard-compliant
model, connect via a fixed terminal block.
Servo amplifier
Servo motor
PE terminal
Control box
CAUTION
3-2 Connection of servo amplifier and servo motor
3-2-1 Connection instructions
Wind insulation tape three or four times.
Servo amplifier side