Specifications
Peripheral Equipment
Type
FR-BEL-0.4K
FR-BEL-0.75K
FR-BEL-1.5K
FR-BEL-2.2K
FR-BEL-3.7K
FR-BEL-7.5K
ABCDE F ✕ LGH
Mounting
screw size
Mass
kg (lb)
Variable dimensions mm (inch)
M3.5
M4
M4
M4
M4
M5
M5
M5
M5
M5
M5
M5
110
(4.33)
130
(5.12)
50
(1.97)
94
(3.7)
1.6
(0.06)
1.6
(0.06)
95
(3.74)
115
(4.53)
6
✕
12
(0.24) ✕ (0.47)
6
✕
12
(0.24) ✕ (0.47)
25
(0.98)
30
(1.18)
120
(4.72)
130
(5.12)
150
(5.91)
150
(5.91)
53
(2.09)
65
(2.56)
75
(2.95)
75
(2.95)
102
(4.02)
1.6
(0.06)
105
(4.13)
115
(4.53)
135
(5.31)
135
(5.31)
6
✕
12
(0.24) ✕ (0.47)
6
✕
12
(0.24) ✕ (0.47)
6
✕
12
(0.24) ✕ (0.47)
6
✕
12
(0.24) ✕ (0.47)
25
(0.98)
30
(1.18)
40
(1.57)
40
(1.57)
110
(4.33)
1.6
(0.06)
2.0
(0.08)
2.0
(0.08)
65
(2.56)
110
(4.33)
102
(4.02)
126
(4.96)
0.5
(1.1)
0.7
(1.5)
1.1
(2.4)
1.2
(2.6)
1.7
(3.7)
2.3
(5.1)
This reactor enables users to boost the servo amplifier’s power factor and reduce its power supply capacity.
The power factor improvement effect of the DC reactor (FR-BEL) is higher than the AC reactor (FR-BAL), the size is compact and
light, and the wiring is easy (The AC reactor uses six wires, and the DC reactor uses two wires). Use of the DC reactor is
recommended.
● Power factor improvement reactor (FR-BEL, FR-BAL)
The following filters are provided as a filter compliant with the EMC directive for the servo amplifier’s power supply.
● EMC filter
DC reactor A
Type
FR-BEL-0.4K
FR-BEL-0.75K
FR-BEL-1.5K
FR-BEL-2.2K
FR-BEL-3.7K
FR-BEL-7.5K
Model
Fig.Applicable servo amplifier
MR-J3-10A
MR-J3-20A
MR-J3-40A
MR-J3-60A
MR-J3-70A
MR-J3-100A
MR-J3-200A
MR-J3-350A
AC reactor B
Type
FR-BAL-0.4K
FR-BAL-0.75K
FR-BAL-1.5K
FR-BAL-2.2K
FR-BAL-3.7K
FR-BAL-7.5K
Model
Fig.Applicable servo amplifier
MR-J3-10A
MR-J3-20A
MR-J3-40A
MR-J3-60A
MR-J3-70A
MR-J3-100A
MR-J3-200A
MR-J3-350A
Servo amplifier
1-phase 230VAC
MR-J3-70A or smaller
Servo amplifier
MR-J3-350A or smaller
L2
L1
NFB MC
FR-BAL
T
S
R
Z
Y
X
Power supply
1-phase
230 VAC
L3
L2
L1
P2
(Note)
P1
NFB MC
FR-BAL
FR-BEL
T
S
R
Z
Y
X
Power supply
3-phase
200 to 230 VAC
Servo amplifier
3-phase 200VAC
MR-J3-350A or smaller
External dimensions
A
B
ConnectionsUnit: mm (inch)
D1
W
H±5 (0.197)
W1C
Mounting screw
D±5 (0.197)
RXSYTZ
E
H
F
A or less
B or less
Name plate
Terminal block–Screw size G
Terminal for
connection
C or less
D
L
2–F ✕ L
notch
Installation leg section
Note: Always disconnect the short bar across
P1-P2 when using the DC reactor.
A
B
Model
Applicable servo amplifier Fig.
MR-J3-10A to 100A
MR-J3-200A
MR-J3-350A
Note: The EMC filters described above are made by Soshin Electric.
HF3010A-UN
HF3030A-UN
D1
45 (1.77 )
57 (2.24 )
55 (2.17 )
75 (2.95 )
70 (2.76 )
100 (3.94 )
Type
FR-BAL-0.4K
FR-BAL-0.75K
FR-BAL-1.5K
FR-BAL-2.2K
FR-BAL-3.7K
FR-BAL-7.5K
Variable dimensions mm (inch)
W
135 (5.31)
135 (5.31)
160 (6.3)
160 (6.3)
220 (8.66)
220 (8.66)
W1
120 (4.72)
120 (4.72)
145 (5.71)
145 (5.71)
200 (7.87)
200 (7.87)
H
115 (4.53)
115 (4.53)
140 (5.51)
140 (5.51)
192 (7.56)
194 (7.64)
D
59 (2.32)
69 (2.72)
71 (2.8)
91 (3.58)
90 (3.54)
120 (4.72)
0
-2.5
0
-2.5
0
-2.5
0
-2.5
0
-2.5
0
-2.5
0
-0.0984
0
-0.0984
0
-0.0984
0
-0.0984
0
-0.0984
0
-0.0984
C
7.5 (0.3)
7.5 (0.3)
7.5 (0.3)
7.5 (0.3)
10 (0.39)
10 (0.39)
Mounting
screw size
Terminal
screw size
Mass
kg (lb)
M4
M4
M4
M4
M5
M5
M3.5
M3.5
M3.5
M3.5
M4
M5
2.0 (4.4)
2.8 (6.2)
3.7 (8.2)
5.6 (12.3)
8.5 (18.7)
14.5 (31.9)
External dimensions
A
B
Connections
Unit: mm (inch)
● HF3010A-UN
● HF3030A-UN
EMC filter
NFB
3
2
1
6
E
5
4
MC
L3
L2
L1
L21
L11
Servo amplifier
OUTIN
(Note)
Power supply
3-phase
200 to 230VAC
or
1-phase
230VAC
Model
HF3010A-UN
Mass
kg (lb)
3 (6.6)
Model
HF3030A-UN
Mass
kg (lb)
5.5 (12.1)
Note: A surge protector is separately required to use this EMC filter.
Refer to “EMC Installation Guidelines”.
Note: A surge protector is separately required to use this EMC filter.
Refer to “EMC Installation Guidelines”.
IN
258 (10.16) ±4 (0.16)
3-M4
3-M4 M4
4-5.5 (0.217) ✕ 7 (0.276)
273 (10.75) ±2 (0.08)
41 (1.61)
65 (2.56) ±4 (0.16)
288 (11.34) ±4 (0.16)
300 (11.81) ±5 (0.20)
32 (1.26) ±2 (0.08)
85 (3.35) ±2 (0.08)
110 (4.33) ±4 (0.16)
Note: For 1-phase 230VAC power supply, connect the power
supply to L1, L2, and leave L3 open. 1-phase 230VAC is
available only for the MR-J3-70M or smaller.
260 (10.24) ±5 (0.20)
210 (8.27) ±2 (0.08)
85 (3.35) ±1 (0.04) 85 (3.35) ±1 (0.04)
140 (5.51) ±2 (0.08)
70 (2.76) ±2 (0.08)
155 (6.10) ±2 (0.08)
140 (5.51) ±1 (0.04)
125 (4.92) ±2 (0.08)
44 (1.73) ±1 (0.04)
3-M5 3-M5
6-R3.24 (0.128) length 8 (0.315)
M4
24