Specifications

Options
Optional regeneration unit
MR-J3-10A
MR-J3-20A
MR-J3-40A
MR-J3-60A
MR-J3-70A
MR-J3-100A
MR-J3-200A
MR-J3-350A
10
10
10
20
20
100
100
30
30
30
30
30
30
100
100
100
100
100
300
300
300
300
500
500
40
40
40
40
40
40
13
13
MR–RB032 MR–RB12 MR–RB30 MR–RB32 MR–RB50
Servo amplifier
model
Built-in regenerative resistor/
tolerable regenerative
power (W)
Optional regeneration unit/tolerable regenerative power (W)
Resistance
value
()
Note: The tolerable regenerative power in the table differs from the regenerative resistor’s rated wattage.
Servo amplifier
5 m (16.4 ft) or less
(Note 1)
Fan
Optional
regeneration unit
Always disconnect the
wire across P-D.
D
P
P
C
G3
G4
C
8.5 (0.33)8.5 (0.33)
125 (4.92)
79 (3.11)
150 (5.91)
142 (5.59)
7 (0.28)
90 (3.54)
100 (3.94)
10
(0.39)
17 (0.67)
318 (12.52)
335 (13.19)
Fan mounting screw
(2-M3 screw)
G4 G3 C P
Mounting screw size: M6
Mounting screw size: M5
Mounting screw size: M6
82.5 (3.25)
350 (13.78)
162.5 (6.40) 12.5
(0.49)
12.5
(0.49)
162.5 (6.40)
133 (5.24)
49 (1.93)
2.3
(0.09)
17
(0.67)
200 (7.87)
12
(0.47)
7 (0.28)
120 (4.72)
8 (0.31)
30 (1.18)
108 (4.25)
217 (8.54)
82.5 (3.25)
Fan mounting screw
(2-M3 screw)
provided on
opposite side
7 (0.276)14 (0.551)
long hole
Window blows in
direction of arrow
G4 G3 C PG4 G3 C P
46.5 (1.83)
235 (9.25)
244 (9.61)
2
1
50
49
MITSUBISHI
MR-TB50
2-ø4.5 (0.177)
25 (0.98)25 (0.98)
2.5 (0.1)
9 (0.35)
50 (1.97)
ø6 (0.236)
mounting hole
LA
LB
LD
1.6 (0.06)
LC
6 (0.24)
TE1
6 (0.24)
156 (6.14)
12 (0.47) 144 (5.67)
6 (0.24)
168 (6.61)
12 (0.47)
20
(0.79)
5
(0.20)
Type
MR-RB032
MR-RB12
Variable dimensions
LA
30 (1.18)
40 (1.57)
LB
15 (0.59)
15 (0.59)
LC
119 (4.69)
169 (6.65)
LD
99 (3.90)
149 (5.87)
Mass
kg (lb)
Mass
kg (lb)
Mass
kg (lb)
0.5 (1.1)
1.1 (2.4)
Type
MR-RB30
MR-RB32
2.9 (6.4)
2.9 (6.4)
Type
MR-RB50 5.6 (12.3)
(Note 2)
Notes: 1.
2.
When using the MR-RB50, always forcibly cool with
the cooling fan (approx. 1.0m
3
/min, M92).
Create a sequence that turns off the magnetic
contactor (MC) when abnormal overheating occurs.
External dimensions ConnectionUnit: mm (inch)
MR-RB032, MR-RB12 MR-RB30, MR-RB32
MR-RB50
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M3
TE1
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M4
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M4
Unit: mm (inch)
Terminal block screw size: M3.5
Compatible wire: 2mm
2
max. (AWG14)
Crimping terminal width: 7.2mm (0.283 inch) max.
Junction terminal block (MR-TB50)
All signals can be recieved with this junction terminal block without a connection to CN1.
Notes: 1. The optional regeneration unit will heat up to approx. 100°C (212°F), so do not directly mount it on a wall susceptible to heat. Use nonflammable wires or provide flame resistant
treatment (use silicon tubes, etc.), and wire so that the wires do not contact the optional regeneration unit.
2. Always use twisted wires for the optional regeneration unit, and keep the length as short as possible (5m (16.4 ft) or less).
3. Always use twisted wires for a temperature detector, and make sure that the detector does not fail to work properly due to inducted noise.
16