Specifications
Standard Wiring Diagram
MR-J3-MA type: Torque control operation
● Connection
DICOM
DOCOM
CN1
20
46
8
9
4
5
6
LZ
7
LZR
LA
34
LAR
33
1
LB
LBR
LG
OP
P15R
SD
PLATE
PLATE
EMG
42
SON
15
RES
19
16
SP1
SP2
RS1
RS2
41
18
17
DOCOM
47
DICOM
2 meters (6.56 ft) max.
10 meters (32.81 ft) max.
21
ALM
48
VLC
25
ZSP
23
P15R
1
TC
27
49
2
LG
VLA
28
SD
(Note 2)
RA1
RA2
RA3
RA4
CN3
CN2
1
P5
2
LG
3
MR
4
MRR
7
MD
8
MDR
9
BAT
SD
PLATE
U
2
3
4
1
1
2
V
W
B1
B2
Servo motor
HF-KP series
Servo motor
HF-SP series
SM
Electromagnetic
brake
(Note 11)
P5
LG
MR
MRR
MD
MDR
BAT
SD
EMG
24VDC
Ready
10 meters (32.81 ft) max.
RD
(Note 10)
30 meters (98.43 ft) max.
SDP
SDN
RDP
RDN
LG
LG
TRE
5
4
3
6
1
7
8
CN6
2 meters (6.56 ft) max.
MO1
3
LG
A
A
1
MO2
2
Servo amplifier
MR-J3-MA
L1
L2
L3
NFB
MC
L11
L21
P
C
D
N
P1
P2
CNP2
CNP1
U
V
W
CNP3
RDP
RDN
SDP
SDN
GND
GND
(Note 9)
(Note 13)
CN5
USB
(Note 8)
VBUS
D
–
D
+
1
2
GND
5
3
3 meters (9.84 ft) max.
VBUS
D
–
D
+
GND
SHELL
(Note 9)
P5
LG
MR
MRR
MD
MDR
BAT
SD
P5
LG
MR
MRR
MD
MDR
BAT
SD
1
2
3
4
7
8
9
PLATE
CN2
RS-422
(Note 12)
SM
A
B
C
D
B1
B2
24VDC
EMG
W
V
U
W
V
U
Create a sequence that cuts off the MC
when an alarm or emergency stop occurs.
Power supply
3-phase
200 to 230VAC
(Note 1)
Optional
regeneration
unit
The servo amplifier could be
damaged if the optional regeneration
unit or power factor improvement DC
reactor is incorrectly connected.
Always disconnect the
connection across P-D
when connecting the
optional regeneration
unit externally.
Always disconnect
the connection
across P1-P2 when
using the FR-BEL.
Power factor
improvement
DC reactor
FR-BEL
(option)
(Note 3)
24VDC power supply
+
–
Control common
Encoder Z-phase pulse
(differential line driver)
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Encoder Z-phase pulse
(open collector)
10 meters (32.81 ft) max.
2 meters (6.56 ft) max.
Speed selection 1
Speed selection 2
Emergency stop
Forward rotation selection
Reverse rotation selection
Reset
Servo on
(Note 4)
(Note 6)
Malfunction
Zero speed detection
Speed limit in effect
Analog torque command
±8V/maximum torque
(in this wiring diagram,
+8V/maximum torque)
Analog speed limit
±10V/rated speed
(in this wiring diagram,
+10V/rated speed)
Upper limit setting
Upper limit setting
Shut off when the servo
on signal turns off and
when alarm signal is issued.
Encoder
Encoder
An encoder cable is available. Refer to the section
“Options ● Cables and Connectors” in this
catalog for details on the cable models.
(Note 11)
Electro-
magnetic
brake
Shut off when the servo
on signal turns off and
when alarm signal is issued.
An encoder cable
is available. Refer
to the section
“Options ● Cables
and Connectors”
in this catalog for
details on the
cable models.
SHIELD
SHELL
MR Configurator
(Setup software)
Personal computer
running Microsoft Windows
Maximum +1mA total
Double oscillation
(±10V output)
Monitor output
Monitor output 1
Monitor output 2
10kΩ
10kΩ
Notes:
1. When using the 1-phase 230VAC (MR-J3-70A or smaller), connect the power supply to L1 and L2. Do not connect anything to L3.
2. Do not reverse the diode’s direction. Connecting it backwards could cause the amplifier to malfunction that signals are not output, and emergency stop and other safety circuits are
inoperable.
3. Use the 24VDC±10% 300 to 900mA power supply. Note that the power capacity differs according to the number of input/output points in use. Refer to “MR-J3-MA SERVO AMPLIFIER
INSTRUCTION MANUAL” for details.
4. EMG (emergency stop) contact (normally closed contact) must be installed. If it is not installed, operation will be impossible.
5. Signals with the same name are connected inside.
6. Malfunction signal (ALM) is turned on during normal operation when no alarms have been triggered.
7. Connect the shield wire securely to the plate inside the connector (ground plate).
8. Max. 3m (9.84ft) is possible in a good noise environment.
9. Refer to “MR-J3-MA SERVO AMPLIFIER INSTRUCTION MANUAL” for details on the connection. Change the parameter No. PC22 when using the 4-wire cable (MR-EKCBL30M-H/-L to
MR-EKCBL50M-H) for the HF-KP series.
10. In the final axis, connect between TRE and RDN.
11. For the motor with an electromagnetic brake. The power supply connected to the electromagnetic brake is not related to the polarity.
12. A personal computer can also be connected with the RS-422/RS-232C conversion cable (refer to “Introductory Parts” in this catalog).
13. This is for sink wiring. Source wiring is also possible. Refer to “MR-J3-MA SERVO AMPLIFIER INSTRUCTION MANUAL” for details.
13