1. FUNCTIONS AND CONFIGURATION
(6) MR-J3-700B(4)-RJ006
MR Configurator
Personal
computer
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
CN5
CN3
CN1A
CN1B
CN2
CN2L
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
Line noise
filter
(FR-BLF)
Power factor
improving DC
reactor
(FR-BEL-(H))
Regenerative option
Servo motor
(Note 3)
Power supply
Servo amplifier
(Note 2)
Load side encoder
R S T
L
11 L21
L3
L
2
L1
U
V
W
PC
P
1
P2
(Note 1)
(Note 1)
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P
1 and P2.
2. For the configuration of the ABZ-phase pulse train interface or serial communication specification linear encoder/rotary encoder,
refer to section 1.10.
3. Refer to section 1.3 for the power supply specification.