Instruction manual

1 - 23
1. FUNCTIONS AND CONFIGURATION
(4) MR-J3-350B-RJ006
P
C
MR Configurator
CN5
CN3
CN1A
CN1B
CN2
CN2L
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
(Note 1)
Power factor
improving DC
reactor
(FR-BEL)
Regenerative option
Servo amplifier
(Note 3)
Load side encoder
R S T
Personal
computer
Line noise
filter
(FR-BLF)
Servo motor
L
1
L
3
L
2
U
P
1
P
2
V
W
(Note 3)
Power supply
L
21
L
11
(Note 1)
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P
1 and P2.
2. For the configuration of the ABZ-phase pulse train interface or serial communication specification linear encoder/rotary encoder,
refer to section 1.10.