Instruction manual

1 - 22
1. FUNCTIONS AND CONFIGURATION
(3) MR-J3-200B(4)-RJ006
Line noise filter
(FR-BSF01)
(Note 2)
Power supply
R S T
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
L21
(Note 1)
Power factor
improving DC
reactor
(FR-BEL-(H))
P
1
U
V
W
Servo amplifier
Servo motor
L
11
L
1
L2
L3
CN5
Personal
computer
MR Configurator
CN3
CN2
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
CN1A
CN1B
CN2L
C
P
Regenerative option
P
2
(Note 3)
Load side encoder
(Note 1)
(Note 4)
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P
1 and P2.
2. Refer to section 1.3 for the power supply specification.
3. For the configuration of the ABZ-phase pulse train interface or serial communication specification linear encoder/rotary encoder,
refer to section 1.10.
4. Connectors (CNP1, CNP2, and CNP3) and appearance of MR-J3-200B-RJ006 servo amplifier have been changed from April
2008 production. For existing servo amplifier, refer to appendix 4.