Instruction manual

1 - 19
1. FUNCTIONS AND CONFIGURATION
1.9 Configuration including auxiliary equipment
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
(1) MR-J3-100B-RJ006 or less
(a) For 3-phase or 1-phase 200V to 230VAC
(Note 1)
Power factor
improving DC
reactor
(FR-BEL)
W
Line noise
filter
(FR-BSF01)
No-fuse breaker
(NFB) or fuse
CN5
Regenerative option
PC
L
11
L
21
P1
P
2
U
V
Servo motor
L
1
L2
L
3
CN1A
CN1B
CN2
R S T
CN2L
(Note 3)
Load side encoder
Magnetic
contactor
(MC)
Junction
terminal
block
MR Configurator
Personal
computer
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
CN3
(Note 2)
Power supply
Servo amplifier
(Note 1)
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P
1 and P2.
2. A 1-phase 200V to 230VAC power supply may be used with the servo amplifier of MR-J3-70B-RJ006 or less.
For 1-phase 200V to 230VAC, connect the power supply to L
1 L2 and leave L3 open. Refer to section 1.3 for the power
supply specification.
3. For the configuration of the ABZ-phase pulse train interface or serial communication specification linear encoder/rotary encoder,
refer to section 1.10.