Instruction manual

App. - 14
A
PPENDI
X
Table: Recommended crimping terminals
Servo amplifier side crimping terminals
Symbol (Note 2) Applicable tool
Crimping terminal Body Head Dice
Manufacturer
a FVD5.5-4 YNT-1210S
(Note 1) b 8-4NS YHT-8S
c FVD14-6 DH-122 DH-112
d FVD22-6
YF-1
E-4 YNE-38
DH-123
DH-113
YPT-60-21
(Note 1) e 38-6
YF-1
E-4 YET-60-1
TD-124
TD-112
YPT-60-21
(Note 1) f R60-8
YF-1
E-4 YET-60-1
TD-125
TD-113
g FVD2-4 Japan Solderless
h FVD2-M3
YNT-1614
Terminal
j FVD5.5-6
k FVD5.5-8
YNT-1210S
l FVD8-6 DH-121 DH-111
m FVD14-8 YF-1 E-4 YNE-38 DH-122 DH-112
n FVD22-8 DH-123 DH-113
YPT-60-21
(Note 1) p R38-8
YF-1
E-4 YET-60-1
TD-124
TD-112
q FVD2-6 YNT-1614
Note 1. Coat the part of crimping with the insulation tube.
2. Some crimping terminals may not be mounted depending on the size. Make sure to use the recommended ones or equivalent
ones.
(9) Terminal block tightening torque
Tightening torque [N m]
Servo amplifier
TE1 TE2 TE3 PE
L
1
/L
2
/L
3
/
U/V/W/
P
1
/P/C/N
L
11
/L
12
MR-J3-10B(1)-RJ006 to
40B(1)-RJ006
60B-RJ006 to
100B-RJ006
60B4-RJ006
100B4-RJ006
200B(4)-RJ006
350B-RJ006
MR-J3-350B4-RJ006
500B(4)-RJ006
700B(4)-RJ006
1.2 0.8 1.2
1.2
1.2 0.8
MR-J3-11KB(4)-RJ006
15KB(4)-RJ006
3.0 3.0
MR-J3-22KB(4)-RJ006
6.0 6.0
1.2