Instruction manual
App. - 12
A
PPENDI
X
(6) Options, peripheral devices
Use the UL/C-UL Standard-compliant products.
Use the no-fuse breaker (UL489 Listed MCCB) or a Class T fuse indicated in the table below.
No-fuse breaker (Note) Fuse
Servo amplifier
Current Voltage AC Current Voltage AC
MR-J3-10B(1)-RJ006 20B-RJ006 30A frame 5A 10A
MR-J3-40B-RJ006 20B1-RJ006 30A frame 10A 15A
MR-J3-60B-RJ006 to 100B-RJ006
40B1-RJ006
30A frame 15A 20A
MR-J3-200B-RJ006 30A frame 20A 40A
MR-J3-350B-RJ006 30A frame 30A 240V 70A 300V
MR-J3-500B-RJ006 50A frame 50A 125A
MR-J3-700B-RJ006 100A frame 75A 150A
MR-J3-11KB-RJ006 100A frame 100A 200A
MR-J3-15KB-RJ006 225A frame 125A 250A
MR-J3-22KB-RJ006 225A frame 175A 350A
MR-J3-60B4-RJ006 30A frame 5A 10A
MR-J3-100B4-RJ006 30A frame 10A 15A
MR-J3-200B4-RJ006 30A frame 15A 25A
MR-J3-350B4-RJ006 30A frame 20A 35A
MR-J3-500B4-RJ006 30A frame 30A 600Y/347V 50A 600V
MR-J3-700B4-RJ006 50A frame 40A 65A
MR-J3-11KB4-RJ006 60A frame 60A 100A
MR-J3-15KB4-RJ006 100A frame 75A 150A
MR-J3-22KB4-RJ006 225A frame 125A 175A
Note. Listed no-fuse breakers are for when the power factor improving reactor is not used.
(7) Capacitor discharge time
The capacitor discharge time is as follows. To ensure safety, do not touch the charging section for 15
minutes after power-off.
Servo amplifier
Discharge
time (min)
Servo amplifier
Discharge
time (min)
MR-J3-10B-RJ006 20B-RJ006 1 MR-J3-200B(4)-RJ006 350B-RJ006 9
MR-J3-40B-RJ006 60B(4)-RJ006
10B1-RJ006
20B1-RJ006
2
MR-J3-350B4-RJ006
500B(4)-RJ006
700B(4)-RJ006
10
MR-J3-70B-RJ006 3 MR-J3-11KB(4)-RJ006 4
MR-J3-40B1-RJ006 4 MR-J3-15KB(4)-RJ006 6
MR-J3-100B(4)-RJ006 5 MR-J3-22KB(4)-RJ006 8