6. TROUBLESHOOTING
6. TROUBLESHOOTING
POINT
Alarms and warnings are basically the same as those of MR-J3- B servo
amplifier. This chapter describes the contents different from those of MR-J3-
B servo amplifier.
As soon as an alarm occurs, make the servo off status and interrupt the main
circuit power.
Remedies for warnings are the same as those of MR-J3- B servo amplifier.
Refer to chapter 8 of the MR-J3-
B Servo Amplifier Instruction Manual.
If an alarm has occurred, refer to this chapter and remove its cause.
6.1 Alarms and warning list
When a fault occurs during operation, the corresponding alarm or warning is displayed. Refer to section 6.2 of
this manual and section 8.2 of the MR-J3-
B Servo Amplifier Instruction Manual at an alarm occurrence and
section 6.3 of this manual and section 8.3 of the MR-J3-
B Servo Amplifier Instruction Manual at a warning
occurrence, and then take the appropriate action. When an alarm occurs, the ALM turns OFF.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
in the alarm
deactivation column. The alarm is automatically canceled after removing the cause of occurrence.
Alarm deactivation Display Name
Display Name Power 96 Home position setting error
OFF ON
Error reset CPU reset
E0 Excessive regeneration warning
10 Undervoltage E1 Overload warning 1
12 Memory error 1(RAM) E4 Parameter warning
13 Clock error E6 Servo forced stop warning
15 Memory error 2(EEP-ROM) E7 Controller emergency stop warning
16 Encoder error 1 (At power on) E8 Cooling fan speed reduction warning
17 Board error E9 Main circuit off warning
19 Memory error 3(Flash-ROM) EC Overload warning 2
1A Motor combination error
Warnings
ED Output watt excess warning
20 Encoder error 2 (During runtime)
21 Encoder error 3 (During runtime)
24 Main circuit error
28 Linear encoder error 2
2A Linear encoder error 1
30 Regenerative error (Note 1) (Note 1) (Note1 )
31 Overspeed
32 Overcurrent
33 Overvoltage
34 Receive error 1 (Note 2)
35 Command frequency alarm
36 Receive error 2
37 Parameter error
42
Fully closed loop control error
detection
(Note 3) (Note 3)
45 Main circuit device overheat (Note 1) (Note 1) (Note 1)
46 Servo motor onerheat (Note 1) (Note 1) (Note 1)
47 Cooling fan alarm
50 Overload 1 (Note 1) (Note 1) (Note 1)
51 Overload 2 (Note 1) (Note 1) (Note 1)
52 Error excessive
70 Load side encoder error 1
71 Load side encoder error 2
8A USB communication time-out error
8E USB communication error
Alarms
888 Watchdog
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. In some controller communication status, the alarm factor may not be removed.
3. Set parameter No.PE03 to "1
" to deactivate.