Instruction manual

3 - 19
3. LOAD SIDE ENCODER
(2) Linear encoder unit structure
Note that the increasing/decreasing directions change depending on the interpolator (MJ830/MJ831)
settings. The following figure shows the moving direction when the MODE switch of the interpolator
(MJ830/MJ831) is set to 5.
Always set an linear encoder home position (reference mark).
Increasing direction
SONY SL700
SONY PL101-R/RH
SH13
For using PL101-R/RH, SL700
For using SH13
Decreasing direction
Decreasing direction
Increasing direction
(3) Outline drawing
(a) SL710
[Unit: mm]
ML - P x (n - 1) 200
(20)
D/2
9
25
20
SL710
P 200
P x (n - 1 or 2)
Mount the scale on a non-magnetic material.
When mounting it on a magnetic material, provide
a non-magnetic layer of 3mm or more.
Effective measurement length (ML)
Full length = effective measurement length + 40
n - D reamed hole
(For D parallel pin insertion)
12 0.05