Instruction manual
2 - 23
2. LINEAR SERVO MOTOR
(2) Mounting the secondary side (magnet)
WARNING
The linear servo motor uses a strong magnet on the secondary side. Therefore,
not only the servo motor installation operators but also the machine operators
must use abundance of caution. For example, one who uses a medical device like
a pacemaker must keep away from the machine.
CAUTION
When mounting the secondary side (magnet), use nonmagnetic tools.
When the additional secondary side (magnet) is mounted after one has been
already set, slide the additional secondary side (magnet) to mount in the specified
position after setting in the position away from the one already mounted as shown
in this section.
When two or more secondary side (magnet) is mounted, set the mounting screw
accumulative pitch tolerance within
0.2mm. Clearance may be left between the
secondary sides (magnets) depending on the mounting method and the numbers.
When using multiple secondary sides (magnets), arrange the name plates attached to the products on the
same side for keeping the layout of magnetic poles.
Caution name plate
In order to decrease the clearance between the secondary sides (magnets), mount them with the following
procedure.
Procedure 1. Securely fix with bolts the secondary side (magnet) to be a mounting standard.
Secondary side
to be a mounting standard
Procedure 2. Set the secondary side (magnet) on the mounting face and fix it with bolts as temporary joint.
Secondary side
to be a mounting standard
Procedure 3. Press the secondary side (magnet) fixed as temporary joint toward that to be a mounting
standard.
Secondary side
to be a mounting standard