Instruction manual

1 - 4
1. FUNCTIONS AND CONFIGURATION
1.3 Function list
The following table lists the functions of this servo. For details of the functions, refer to the reference field.
Function Description Reference
Absolute position detection
system
Merely setting a home position once makes home position return
unnecessary at every power-on.
Section 5.7
Gain changing function
You can switch between gains during rotation and gains during stop or use
an external signal to change gains during operation.
Advanced vibration
suppression control
This function suppresses vibration at the arm end or residual vibration.
Adaptive filter
Servo amplifier detects mechanical resonance and sets filter characteristics
automatically to suppress mechanical vibration.
Low-pass filter
Suppresses high-frequency resonance which occurs as servo system
response is increased.
MR-J3-B Servo
Amplifier Instruction
Manual
Machine analyzer function
Analyzes the frequency characteristic of the mechanical system by simply
connecting a servo configuration software-installed personal computer and
servo amplifier.
MR Configurator (servo configuration software) MRZJW3-SETUP221E is
necessary for this function.
Machine simulation
Can simulate machine motions on a personal computer screen on the basis
of the machine analyzer results.
MR Configurator (servo configuration software) MRZJW3-SETUP221E is
necessary for this function.
Gain search function
Personal computer changes gains automatically and searches for overshoot-
free gains in a short time.
MR Configurator (servo configuration software) MRZJW3-SETUP221E is
necessary for this function.
Slight vibration suppression
control
Suppresses vibration of
1 pulse produced at a linear servo motor stop.
Auto tuning
Automatically adjusts the gain to optimum value if load applied to the linear
servo motor shaft varies. Higher in performance than MR-J2-Super series
servo amplifier.
Brake until
Used when the regenerative brake option cannot provide enough
regenerative power.
Can be used with the servo amplifier of 5kW or more.
Return converter
Used when the regenerative brake option cannot provide enough
regenerative power.
Can be used with the servo amplifier of 5kW or more.
Regenerative brake option
Used when the built-in regenerative brake resistor of the servo amplifier
does not have sufficient regenerative capability for the regenerative power
generated.
Alarm history clear Alarm history is cleared.
Output signal (DO)
forced output
Output signal can be forced on/off independently of the servo status.
Use this function for output signal wiring check, etc.
Test operation mode
Positioning operation
DO forced output.
However, MR Configurator (servo configuration software) MRZJW3-
SETUP221E is necessary for positioning operation.
MR-J3-B Servo
Amplifier Instruction
Manual
Analog monitor output Servo status is output in terms of voltage in real time. Parameter No. PC09
MR configurator
(Servo configuration software)
Using a personal computer, parameter setting, test operation, status display,
etc. can be performed.
Section 5.4